The board tool wrote pick-and-place rotations in its own footprint frame while JLCPCB counts rotation from its own library footprint, so for SOIC-8, DFN, SOT-23 and WS2812B pin 1 sits in a different corner and JLCPCB engineers hand-corrected every such part.
Import, export & interop reported against 4k7 (hoihu)
What engineers report
A import, export & interop reported against 4k7 (hoihu): breaks when reading, writing or converting files and data between tools.
Recorded mode: validation / assembly data gap
Analyst note
From the Grok pain-radar digests, Oct 26-27 2026 (Oct 26 12:41 PM ET through Oct 27 7:41 AM ET digests plus the Haitch editions). Verified live 2026-10-27: issue/PR/thread read; title and state confirmed.
What it costs a team
Modeled annual cost
$30,000
For a team of 5
Prototype delay
3 days
Modeled schedule slip per occurrence
Time lost
240 min
Per engineer per month, about 1 incidents
How the cost is modeled
240 min/month × 5 engineers × 12 months = 240 hours × $125/hour = $30,000
A modeled estimate with medium confidence. Swap in your own team size and loaded rate to size it for your team.
Engineering tools that address it
No engineering tool profile lists this error yet. Browse tools that connect to 4k7 (hoihu).
Evidence
More recurring errors in 4k7 (hoihu)
- On a real RP2040 board, six supply symbols stood in one column with a +1V1 stem running along a +3V3 stem, which read like a short. The in-app agent answered that fixing it needs symbol moves this run does not allow, and tried nothing. The fix changes both the drawing logic and what the agent is told about automatic symbols.Electronics & PCB · impact 74
- 4k7 schematic Issues list had 40 of 42 entries on spiral2 about how wires were drawn. Drawing findings now drop out of the Issues list and counts so the agent and the user see what is wrong with the circuit.Electronics & PCB · impact 66
- JLCPCB could not place two SMD electrolytics: pads were chip-style strips as tall as the can, and one part was a 6.3 mm can on pads for an 8 mm one, and the stock check had flagged both by package name but similar-looking names made it easy to dismiss.Electronics & PCB · impact 66
- Two empty schematic sheets took a page each, and nothing could delete them. On Oct 27 the in-app agent moved everything back to Main and asked the user to remove the sheets in the app, which could not do it either.Electronics & PCB · impact 66
Sourced from public community reports. Costs and delays are modeled estimates, not measurements. Know a better source or a fix? Tell us at hello@productflo.io.