Checking the rev 2 cable against Molex's drawings showed the 50 mm FFC ribbon did not fit, so it became a custom flex jumper. Along the way a connector pad sat 0.21 mm from a socket tab (now 0.6 mm), and F1's top-side solder joint sat under the other connector, which the placement check missed until it learned to compare pad copper against the opposite face's courtyards.
Wrong verdict reported against compose-keyboards (edulpn)
What engineers report
A wrong verdict reported against compose-keyboards (edulpn): a check, review or gate reports pass or fail incorrectly.
Recorded mode: validation / failure
Analyst note
From the Grok pain-radar digests, Nov 8-9 2026 (Nov 8 8:41 AM ET through Nov 9 6:41 AM ET digests plus the Haitch editions). Verified live 2026-11-09: issue/PR read; title and state confirmed.
What it costs a team
Modeled annual cost
$30,000
For a team of 5
Prototype delay
3 days
Modeled schedule slip per occurrence
Time lost
240 min
Per engineer per month, about 1 incidents
How the cost is modeled
240 min/month × 5 engineers × 12 months = 240 hours × $125/hour = $30,000
A modeled estimate with medium confidence. Swap in your own team size and loaded rate to size it for your team.
Engineering tools that address it
No engineering tool profile lists this error yet. Browse tools that connect to compose-keyboards (edulpn).
Evidence
More recurring errors in compose-keyboards (edulpn)
- A review of a keyboard's board generators and checks: two DRC commands printed their counts and exited 0 no matter what, a jumper row was solved in a second imported copy of a module so the command kept a cached 0.72 start value that ends up 1.0 mm off at 6 degrees of splay, and the cache key ignored the tent angle so a row computed for one tent got reused for another. The crosstalk sweep still listed a net that had been renamed. Every one of these looked fine from the outside.Electronics & PCB · impact 66
- Follow-up to PR #6: the LED orientation check took each pin's position from the board plan's own table, so a wrong table passed, and it now reads what each lead connects to from the copper and compares against two published SK6812 MINI-E footprints. Every routed via had also come back at the default 0.6/0.3 mm instead of the size the router placed, and a truncated ngspice run was being analyzed as if it had finished. A check that reads its answer from the same source as the design cannot fail.Electronics & PCB · impact 66
Sourced from public community reports. Costs and delays are modeled estimates, not measurements. Know a better source or a fix? Tell us at hello@productflo.io.