The text fallback parser this MCP server uses when pcbnew is not importable read a real 2-layer board (179 segments, 33 vias, 24 nets) as 0 tracks when the file was KiCad 9 format, and gave 0 of 33 vias a net in both KiCad 9 and KiCad 10 formats. An agent calling get_pcb_statistics or find_tracks_by_net got an empty or netless board back, with no error. The fix parses each block properly and was checked against pcbnew.LoadBoard() from KiCad 10.0.4.

Silent failure reported against kicad-mcp-server (Seeed-Studio)

kicad-mcp-server (Seeed-Studio)Electronics & PCBSilent failureMedium confidence

What engineers report

A silent failure reported against kicad-mcp-server (Seeed-Studio): reports success, or uses stale data, while the result is wrong or missing.

Recorded mode: agent / silent failure

Analyst note

From the Grok pain-radar digests, Nov 13-14 2026 (Nov 13 10:41 AM ET through Nov 14 7:41 AM ET digests plus the Haitch editions). Verified live 2026-11-14: issue/PR read; title and state confirmed.

What it costs a team

Modeled annual cost

$30,000

For a team of 5

Prototype delay

3 days

Modeled schedule slip per occurrence

Time lost

240 min

Per engineer per month, about 1 incidents

How the cost is modeled

240 min/month × 5 engineers × 12 months = 240 hours × $125/hour = $30,000

A modeled estimate with medium confidence. Swap in your own team size and loaded rate to size it for your team.

Engineering tools that address it

No engineering tool profile lists this error yet. Browse tools that connect to kicad-mcp-server (Seeed-Studio).

Evidence

  1. 1Seeed-Studio/kicad-mcp-server PR #34: fix(pcb_parser): parse tracks/vias for KiCad 9 net codes and KiCad 10 namesgithub.com

More recurring errors in kicad-mcp-server (Seeed-Studio)

See all 3 kicad-mcp-server (Seeed-Studio) errors

Sourced from public community reports. Costs and delays are modeled estimates, not measurements. Know a better source or a fix? Tell us at hello@productflo.io.