After deploying v5.0.0-alpha, real KiCad designs got no schematic model: KiCad 9 private fields failed the whole schematic, a case-differing sub-sheet name failed on the Linux worker, and two mounting pads sharing a pin number got the same pin UUID, breaking the compiled graph.
Wrong verdict reported against KiCAD-Prism (krishna-swaroop)
What engineers report
A wrong verdict reported against KiCAD-Prism (krishna-swaroop): a check, review or gate reports pass or fail incorrectly.
Recorded mode: agent / false failure
Analyst note
From the Grok pain-radar digest, Oct 24-25 2026 (Oct 24 evening to Oct 25 morning slots). Verified live 2026-10-25: issue/PR read on GitHub; title and state confirmed.
What it costs a team
Modeled annual cost
$30,000
For a team of 5
Prototype delay
3 days
Modeled schedule slip per occurrence
Time lost
240 min
Per engineer per month, about 1 incidents
How the cost is modeled
240 min/month × 5 engineers × 12 months = 240 hours × $125/hour = $30,000
A modeled estimate with medium confidence. Swap in your own team size and loaded rate to size it for your team.
Engineering tools that address it
No engineering tool profile lists this error yet. Browse tools that connect to KiCAD-Prism (krishna-swaroop).
Evidence
More recurring errors in KiCAD-Prism (krishna-swaroop)
- A fitted part with neither an MPN nor an LCSC number was never stored as a BOM line. On a USB-PD trigger board, connector J2 disappeared, and the supply page showed '17 of 17 lines', 100% coverage and '10 of 10 boards' buildable. The fix counts it as unchecked, so coverage now reads 94%.Electronics & PCB · impact 74
- A release BOM over 20,000 rows was silently cut to a prefix and assessed as if complete; DeepSeek did the first pass of the fixes and the author corrected two of its changes.Electronics & PCB · impact 74
- Alternate parts were approved without recording which main part they were reviewed against, so a new reviewed_against column now shows 'vs NEW, was vs OLD' when the main part changed.PLM & data · impact 74
- For repos with several KiCad projects in subfolders, every jobset job succeeds but nothing gets committed; the log ends with a 'Git sync warning', outputs sit untracked, and the Assets Portal shows 'No files found' for design and manufacturing outputs. kicad-cli also rewrote the .kicad_prl during the run, so the checkout is dirty and the next Sync cannot fast-forward.Electronics & PCB · impact 74
- is_fitted only matched 'DNP = yes' while KiCad's BOM export writes DNP, Excluded from BOM, 1 or x across several columns, and BOM lines with no tracked part or stock reading were counted as fine.Electronics & PCB · impact 74
- When the board is behind its schematic, two distinct schematic nets with pins on the same stale board net got folded together and inspected under the board's old name. The fix only applies when more than one schematic net claims a board net.Electronics & PCB · impact 74
Sourced from public community reports. Costs and delays are modeled estimates, not measurements. Know a better source or a fix? Tell us at hello@productflo.io.