KiCadRoutingTools, a chained autorouting flow. route_diff.py connects the USB D+/D- pair single-ended but records no protection for it. The next step, route.py, rips both nets as "pre-existing", never reroutes them, skips the restore because the old copper would now short, and the improvement gate logs "this run broke 2 previously-connected net(s) [D+, D-] ... ACCEPTED". The board ships with D+, D-, SDA and SWDIO open. One step's knowledge didn't reach the next step.
Wrong verdict reported against KiCadRoutingTools (drandyhaas)
What engineers report
A wrong verdict reported against KiCadRoutingTools (drandyhaas): a check, review or gate reports pass or fail incorrectly.
Recorded mode: agent / false pass
Analyst note
From the Grok pain-radar digests, Nov 22-23 2026 (Nov 22 8:41 AM ET through Nov 23 7:41 AM ET digests). Verified live 2026-11-23: issue/PR read; title and state confirmed.
What it costs a team
Modeled annual cost
$30,000
For a team of 5
Prototype delay
3 days
Modeled schedule slip per occurrence
Time lost
240 min
Per engineer per month, about 1 incidents
How the cost is modeled
240 min/month × 5 engineers × 12 months = 240 hours × $125/hour = $30,000
A modeled estimate with medium confidence. Swap in your own team size and loaded rate to size it for your team.
Engineering tools that address it
No engineering tool profile lists this error yet. Browse tools that connect to KiCadRoutingTools (drandyhaas).
Evidence
More recurring errors in KiCadRoutingTools (drandyhaas)
- A .kicad_dru rule says HV nets need 0.6 mm, but route.py prints it as handled, lists no unsupported rules, and ships HV copper 0.2 to 0.58 mm apart. With --clearance-ceiling 0.1 it also rewrites the .kicad_pro HV class to 0.1 mm, so kicad-cli DRC and check_drc both report a clean board.Electronics & PCB · impact 82
- A class-scoped disallow track layer rule is treated as consumed. route.py puts 11 HS tracks on B.Cu, check_drc says clean, board_score reports 0 blocking, while KiCad itself reports 11 items_not_allowed.Electronics & PCB · impact 82
- On the orbiter_kb board the final route step ships GND open, and only KiCad's refill catches it. The copper grading passed it. The tool's fill model counts a 106 mm2 B.Cu island as joined to the main flood, and KiCad does not, and the repair step cannot weld the link either, because kicad-cli anchors the zone end at an outline corner that sits off the board.Electronics & PCB · impact 82
- A routed board passes check_drc, board_score and check_complete after its floors are lowered, but the grade against the authored project reads UNSOUND, and KiCad finds about 170 clearance errors at the authored project.Electronics & PCB · impact 74
- A weld moved a track to 0.1304 mm from a foreign via against 0.2 mm clearance, and the sweep's gate only checks the net's own connectivity.Electronics & PCB · impact 74
- An escape via cut a guarded pour, two pads ended open and the gate accepted.Electronics & PCB · impact 74
Sourced from public community reports. Costs and delays are modeled estimates, not measurements. Know a better source or a fix? Tell us at hello@productflo.io.