FreeCAD MCP bridge (neka-nat/freecad-mcp)MCADConfidence: Medium
When an agent fans out parallel create calls through the FreeCAD MCP bridge, the shared connection races: the first object is created even though its call reports failure, and the second object is silently never created with the status still showing healthy.
From the 2026-10-07 pain-radar digest (findings 2): maintainer fixed the same day with 14 new concurrency tests. The failure shape is general to single-threaded CAD engines (FreeCAD, SolidWorks), not just this bridge. Cost model assumes the engineer must manually reconcile every parallel call against live model state.