The IFC geometry crate returns metres and radians when a file declares no length unit, and callers cannot tell that from a file that really says metres. 'A model in millimetres without a unit assignment is placed 1000x too large, silently.' In one path a failed unit conversion error is discarded and the default kept.
From the Grok pain-radar digests, Oct 28-29 2026 (Oct 28 8:41 AM ET through Oct 29 early-morning Haitch editions). Verified live 2026-10-29: issue/PR read; title and state confirmed.