helixscreen (prestonbrown) errors
3 failures reported against helixscreen (prestonbrown), sorted by how they fail and ranked by impact.
#195 by errors trackedEmbedded & firmwareSimulation & verification
Recurring helixscreen (prestonbrown) errors, by impact
- 1make land-gate passed a change that does not compile for ESP32 firmware because the gate's ESP32 compile step returns at once outside staged mode; the '28 TU(s) clean' log line was the host syntax check. Only pre-push caught it.Embedded & firmware · Wrong verdict · 1 report74
- 2Klipper touchscreen gives up on an extruder MPC calibration at a hard 20 minute timeout and shows "calibration failed". Klipper finished 36 seconds later. The result was never saved, and the user had to send SAVE_CONFIG by hand.Simulation & verification · Wrong verdict · 1 report66
- 3The pre-print fit check on a Snapmaker U1 reads nozzle sizes from the config file, which says 0.4 on all four heads, while the firmware's real status says 0.2/0.4/0.4/0.6, two of them high flow. It also judges heads the job does not use and never checks flow type, which the firmware refuses at print start.Embedded & firmware · Wrong verdict · 1 report66
How it fails
Sourced from public community reports. Costs and delays on individual entries are modeled estimates, not measurements.