#84 by errors trackedElectronics & PCB
Recurring kicad-autorouter (hulryung) errors, by impact
- 1A CHASSIS net class set to 0.5 mm got about 300 mm of 0.2 mm track in auto mode. DRC passes it because the board minimum is 0.1 mm, so nothing flags it. The GUI saves netclass mode, but the script defaults are auto, so scripts and benchmarks quietly get the narrow tracks. Same intent, two defaults.Electronics & PCB · Silent failure · 1 report66
- 2An autorouter ignores a route the engineer locked in by hand. A relay coil net was pre-routed pad to stub to via to an In2 lane ending in the open. The router didn't continue from the lane end. It laid a new 41.7 mm B.Cu track parallel to it from the pad, and a second net crossed the whole cell. The ask is to treat free ends of existing tracks, locked ones included, as anchors the way KiCad's ratsnest does. Automation that can't read the human's partial work redoes it badly.Electronics & PCB · Wrong design output · 1 report66
- 3An autorouter joining USB D+ and D- pads on a USBLC6-2SC6 (SOT-23-6, pads 0.6 x 1.3 mm) dropped 0.6 mm vias right in the pad centres and bridged on B.Cu. The via is as wide as the pad. KiCad DRC doesn't flag it, and an unfilled via in a small SMD pad wicks solder. The engineer moved the vias 0.7 mm past the pad ends by hand with no DRC change. The ask is to forbid via-in-pad unless the fab preset says filled vias. Whether that's allowed is a fab decision, and the router never sees it.Electronics & PCB · Silent failure · 1 report66
- 4An autorouter run closed off the GND pour corridor to two QFP pads on a 4-layer board. After refill both pads had no copper of their net and KiCad DRC showed 2 unconnected. The job itself said nothing, and rerunning reports 0/0 because plane-net pads never count as connections. The workaround was hand-placed keepouts and a rerun from the original board.Electronics & PCB · Silent failure · 1 report66
- 5Locked hand-routed tracks get split or nudged 0.02 mm where a new route joins. The pieces get new UUIDs and lose the lock, so restoring locks by UUID misses them and a board diff shows hand copper removed and re-added.Electronics & PCB · Silent failure · 1 report66
- 6Nets KiCad names automatically, like Net-(J7-TD+) and Net-(J7-TD-), aren't recognised as differential pairs because the suffix match expects the name to end in + or -, and these end in ). So they get routed single-ended, drop out of the pair-length stats and skip the new pair lock. Nothing warns. The pair exists in the designer's head and in a naming convention, not anywhere the tool can read for sure.Electronics & PCB · Silent failure · 1 report66
How it fails
Sourced from public community reports. Costs and delays on individual entries are modeled estimates, not measurements.