A KiCad DRC import dropped the list of checks the board's settings ignore, so a clean report could vouch for a check that never ran. The fix writes each ignored check into a skipped list, and a review item covered by another tool's report is never marked pass, only 'covered externally'.
Recurring agent failure issue in agni (panyam)
What engineers report
A recurring agent failure problem in agni (panyam) that mostly hits the electrical engineer.
Failure pattern: agent / false pass
Analyst note
From the Grok pain-radar digests, Nov 10-11 2026 (Nov 10 8:41 AM ET through Nov 11 7:41 AM ET digests plus the Haitch editions). Verified live 2026-11-11: issue/PR read; title and state confirmed.
What it costs a team
Modeled annual cost
$30,000
For a team of 5
Prototype delay
3 days
Modeled schedule slip per occurrence
Time lost
240 min
Per engineer per month, about 1 incidents
How the cost is modeled
240 min/month × 5 engineers × 12 months = 240 hours × $125/hour = $30,000
A modeled estimate with medium confidence. Swap in your own team size and loaded rate to size it for your team.
Engineering tools that address it
No engineering tool profile lists this error yet. Browse tools that connect to agni (panyam).
Evidence
More recurring errors in agni (panyam)
- An open-source hardware review engine has a BOM tier in its data model, but only its IPC-2581 reader fills it. For every netlist-based design, part numbers come from whatever the schematic symbol carried, while the real bill of materials is a spreadsheet maintained separately from the netlist, so no check can ask whether the netlist and the BOM agree.PDM · impact 74
- A KiCad schematic viewer could light a wire under the wrong net, and a stale sheet view stayed docked and was reported to an agent. After the tab switched from design A to design B, A's sheet view stayed open, and GetLocation listed it to an agent. KiCad wires with no net id were highlighted by name, so they would light under any net with the same name. The fix closes views when the design changes and adds a test that every wire on a pinned net carries its id (132 wires over 50 fixtures).ECAD · impact 66
- Teams keep their MCU pin-mux table in a separate hand-transcribed file, so until hand-merged into the part spec, the pin map check marked every declared function not-considered.ECAD · impact 66
- Teams name nets after the connection they make, and nothing checks the name against the netlist. A net can claim to run between two pins and run somewhere else while every check passes, and copy-pasted names and names left stale after an edit go unnoticed.ECAD · impact 66
- When a vendor reissues a datasheet, the review tool knows a verified value is stale but not what changed, so a reviewer reads both PDFs side by side. A reissue usually changes a few rows, like a tightened absolute maximum, and any one can move a board from passing to marginal, but the stale list gives no hint which rows moved.ECAD · impact 66
Sourced from public community reports. Costs and delays are modeled estimates, not measurements. Know a better source or a fix? Tell us at hello@productflo.io.