CamCraft 3D Pocket applies stock-to-leave only sideways. On a dome test part with 0.5 mm stated, the roughing pass leaves 0 at the apex and the floor and 0.21 to 0.38 mm on the flanks. The finishing pass gets less material than the user asked for, and none in some places. Found by reading the posted program, not on a machine.
Wrong design output reported against Camcraft (NeoTech)
What engineers report
A wrong design output reported against Camcraft (NeoTech): produces incorrect geometry, routing, values or parts.
Recorded mode: validation / failure
Analyst note
From the Grok pain-radar digests, Nov 22-23 2026 (Nov 22 8:41 AM ET through Nov 23 7:41 AM ET digests). Verified live 2026-11-23: issue/PR read; title and state confirmed.
What it costs a team
Modeled annual cost
$30,000
For a team of 5
Prototype delay
3 days
Modeled schedule slip per occurrence
Time lost
240 min
Per engineer per month, about 1 incidents
How the cost is modeled
240 min/month × 5 engineers × 12 months = 240 hours × $125/hour = $30,000
A modeled estimate with medium confidence. Swap in your own team size and loaded rate to size it for your team.
Engineering tools that address it
No engineering tool profile lists this error yet. Browse tools that connect to Camcraft (NeoTech).
Evidence
More recurring errors in Camcraft (NeoTech)
- Contour a 40 x 40 x 30 box with a 4 mm cutter that has 12 mm flutes and a 6 mm shank. verify returns 'ok': true with 84 findings, every one marked shank_hit and blocks_post. The Fanuc post then refuses with 84 warnings. A 3D finish on a test STEP gives ok: true with 3,232 blocking findings. The hits are real, the summary flag is wrong.Mechanical · impact 74
- The issue behind PR #713: CAM refuses to post a tap because CAD models the hole the normal way, at tap-drill size, while the gouge check sweeps the tap at full major diameter. The only way through was to remodel the hole at the thread's major diameter, which makes the CAD wrong.Mechanical · impact 74
- The STEP importer never reads LENGTH_UNIT, so a metre file imports 1000 times too small and an inch file 25.4 times too small, with no message either way. Such a part generates, verifies and posts a correct-looking CAM program at the wrong size, and no import scale command exists to fix it after the fact.Mechanical · impact 74
- A CAM tool's QA run made a plain plate, 160 x 70 x 15 mm with a pocket and one 6 mm through hole sitting on the pocket wall. The CAD tool that made it measures it exactly (volume and area match the hand calculation, 13 faces, closed). The CAM import refuses both the STEP and the native file. The error calls the STEP corrupt and says to re-export or import an STL. The tessellator gives up on the hole's cylindrical face because its top edge steps from Z 15 to Z 11. The ask is either to import it or to name the face and the reason in terms a user can act on.Mechanical · impact 66
- A consistently inward-wound closed solid imports with negative volume (-102000 mm3 on a real test part). Nothing flips it and the notes stay empty, so a STEP solid imports inside out and nothing says so.Mechanical · impact 66
- A plain cylinder exported from CAD was refused as if a feature crossed the rotary seam because a refinement leaned the axis by tens of microradians on rounding noise.Mechanical · impact 66
Sourced from public community reports. Costs and delays are modeled estimates, not measurements. Know a better source or a fix? Tell us at hello@productflo.io.