EasyCirq (zsx3896926) errors
3 recurring problems engineers report in EasyCirq (zsx3896926), ranked by impact.
#163 by errors trackedECAD
Recurring EasyCirq (zsx3896926) errors, by impact
- 1An agent PCB flow added a gate for two ways to get a fake DRC pass: loosening the rules, for example a diff-pair tolerance going from 0.254 mm to 3.81 mm until DRC hits zero, and running DRC on a copper pour that was not rebuilt after the last copper change.ECAD · Agent failure · 1 report74
- 2The pipeline summary reads 6 PASS, 1 PASS_WITH_WAIVER, 0 BLOCKED, exit code 0, while the BOM cannot be ordered: one resistor line has 0 stock and a 10,000 minimum pack, and five lines are internal library numbers whose store pages return Page Not Found.ECAD · Agent failure · 1 report74
- 3A 4-layer ESP32-S3 camera board with 81 parts driven through JLC EDA Pro with an agent skill took about 25 stages and 40 temporary scripts to reach native DRC 0, with GND stitching sealing off camera signal nets until torn out, the autorouter fallback timing out with leftover segments, and copper ops not deduplicated after an interruption.ECAD · Agent failure · 1 report66
How it fails
Sourced from public community reports. Costs and delays on individual entries are modeled estimates, not measurements.