kicad-cli-extended (Hybirdss) errors
9 recurring problems engineers report in kicad-cli-extended (Hybirdss), ranked by impact.
#49 by errors trackedECAD
Recurring kicad-cli-extended (Hybirdss) errors, by impact
- 1After an autoroute added 9 DRC errors, fab package still produced a JLC Gerber zip marked complete true with exit 0, unless the caller remembered a --fail-on-drc flag. The author's own words: an agent that gates on complete would send a shorted board to the fab.ECAD · Agent failure · 1 report74
- 2On KiCad's pic_programmer demo, pcb place near put a VCC pad on another net's track and exited 0, so DRC later found shorts and solder mask bridges. The update step also reported unrouted connections using pre-placement coordinates about 100 mm off, and a worker crash reported placed.skipped with exit 0.ECAD · Agent failure · 1 report74
- 3An agent branches on the tool's exit code and stdout, and several paths sent it the wrong way: a rolled-back save printed a success-shaped result, two processes editing one project failed as an internal error, and a refusal before any save said commit_state unknown, which the skill tells the agent means repair storage.ECAD · Agent failure · 1 report66
- 4An autoroute threw away 651 seconds of routing. Grid auto refinement failed on its last step after 651 s on pic_programmer, exit 2, nothing saved. The DRC before/after gate also counted unrouted connections as new errors, so a partial route was refused and nothing saved. Follow-up to PR #10 from the 7:41 sweep.ECAD · Agent failure · 1 report66
- 5On a non-English machine every ERC fix hint came back null because the wrapper parsed kicad-cli's translated messages. On KiCad 10.0.8 a valid STEP export got reported as a crash because the check looked for an English log line that build no longer prints.ECAD · Agent failure · 1 report66
- 6The autoroute and placement gates compare KiCad DRC before and after an edit by item UUID. KiCad 5 boards store no UUIDs for pads or some tracks, so every load invents new ones and every old finding looked new. A routing edit far from the problem exited with DRC has 1 new error(s) and a placement was refused. Two earlier fixes matched findings by position, then by position and description, and reviewers broke both.ECAD · Agent failure · 1 report66
- 7The autoroute reported routed 21, failed 0 while DRC went from 0 to 9 errors, because the router used fixed 0.6/0.3 mm vias against the board's 0.9/0.5 mm minimums and ignored copper text. Sizes now come from the board rules, and any new DRC error exits 3 without saving.ECAD · Agent failure · 1 report66
- 8The first write to a KiCad 9 board upgrades it to KiCad 10 format, so the ECO compare flagged format-only changes as unexpected. A correct one-part change failed with 72 entries while a track-by-track check found none of 815 tracks and vias moved.ECAD · Agent failure · 1 report66
- 9With every track ripped, grid auto kept refining down to 0.05 mm and then failed with Grid too large after 651 s, exit 2, nothing saved. Separately the new before/after DRC gate refused partly routed nets because leftover unrouted connections name the new tracks.ECAD · Agent failure · 1 report66
How it fails