Redline (DSI-codebase) errors
3 recurring problems engineers report in Redline (DSI-codebase), ranked by impact.
#196 by errors trackedVerificationPLM
Recurring Redline (DSI-codebase) errors, by impact
- 1PyDRC moved its seven electrical rules out of drc-base into a new pack, but Redline hard-coded drc-base as its default and nothing in the app ever writes that setting, so every install would have run drafting rules only and dropped the electrical ones with no error while all 72 audit and import tests passed.Verification · Agent failure · 1 report74
- 2The installed electrical design app stopped every calculation with no NEC 2026 table '240.4-D'. The packaging step only bundled YAML, and the 28 calculator tables are JSON, so none shipped. The self-test passed because building the window reads no table, and the PR adds a bundle check that compares installed files against the package's own data.Verification · Agent failure · 1 report74
- 3DRC waivers now carry the document an approval rests on, and the work found the manual claimed every export names who waived each finding while the CSV never did.PLM · Agent failure · 1 report66
How it fails